KEPL Range of Panels

Power and Motor Control Center

KEPL Panels RangeKEPL Panels Range
Power and Motor Control Unit 02Power and Motor Control Unit 02
Power and Motor Control Unit 03Power and Motor Control Unit 03

Specification

Application System
Control from Remote Location
Reference Standard
IS 13947
Operational Voltage
24/110/230 V AC/DC 690V AC
Degree of Protection
IP 4x, 5x, x2, x4
Form of Separation
2b/3b/4b
Configuration
Fixed and Draw-Out Type
Drawout Option
Available

Power Factor Corrections Pannel

KEPL Correction PanelKEPL Correction Panel
KEPL Correction Panel 02KEPL Correction Panel 02

Specification

Specification
Power Range
35…500 kVAr
Rated System Voltage
440 V/415 V / 400 V/380 V
Rated Frequency
50 Hz
Duty
Continuous
Ambient Temperature
-5°C to 45°C
Power Supply
3Phase, 4 wire
Ingress protection
Upto IP52
Detuned Reactors
w/o reactor, with 7% & 14% reactors
Switching
Capacitor duty Contactors or Thyristor

DG Synchronisation Paneland Motor Control Center

KEPL DG SynchronisationKEPL DG Synchronisation

Specification

Application
Control and synchronize DG sets, PLC based Load sharing and Load Management
Power supply
3Phase 4 wire
Rated Voltage
415 V
Rated Frequency
50 Hz
Degree of Protection
IP 4x, 5x, x2, x4
Ambient Temperature
-5°C to 45°C
Busbar options
Copper / aluminium

Automation and Drive

KEPL Automation and Drive PanelKEPL Automation and Drive Panel

Specification

Application
Drives for motor application to save energy and space
Power supply
3Phase 4 wire
Rated Voltage
415 V
Rated Frequency
50 Hz
Degree of Protection
IP 4x, 5x, x2, x4
Ambient Temperature
-5°C to 45°C
Busbar options
Copper / aluminium

Auto Transformer Starter & Closed Transition Starter Pannel

KEPL Transformer and Transition starter panelKEPL Transformer and Transition starter panel
Specification
Application
ATS – Suitable for motors with longer acceleration time and high starting torque CTS – No Break in supply to motor during starting
Motor Rating
110….700kW
Power supply
3Phase 4 wire 50Hz
Rated Voltage
415 V
Rated Frequency
50 Hz
Degree of Protection
IP 4x, 5x, x2, x4
Transition Resistors (CTS)
50….500 Amps
Standard Tapping (ATS)
50%, 65% & 80%

Soft Start Panel

KEPL Soft Start PanelKEPL Soft Start Panel
KEPL Soft Start Panel 02KEPL Soft Start Panel 02

Specification

Application
Soft Starters offer soft starting and stopping of the motor. Centrifugal pump, Compressor, Conveyor belt, Elevators, etc.
Rated Motor Current
30….1200Amps
Main Motor Voltage
208-600V
Power supply
3Phase 4 wire 50Hz
Control Supply Voltage
100…250V
Degree of Protection
IP 4x, 5x, x2, x4
Ambient Temperature
-5°C to 45°C

Control Desk

KEPL Control DeskKEPL Control Desk

Specification

Application
Control & status with mimic diagram depicting system layout
Operational Voltage
24/110/230V AC/DC
Rated Frequency
50 Hz
Degree Of Protection
630…3150 A
Short-circuit breaking current
IP 4x, 5x, x2, x4
Ambient Temperature
-5°C to 45°C